Previous
Next
- High power PCB relay with 40A rating.
- USA & European footprint are both available.
- Open frame, dust cover, flux-free type, and sealed type are available.
- Offering SPNC, SPNO, SPDT of contact configurations.
- RoHS Compliant ; ELV Compliant.
Ordering Information
822 |
E |
□ |
– |
1A |
– |
□ |
□ |
|||
1 |
2 |
3 |
4 |
5 |
6 |
1. | 822 | — | Basic series designation |
2. | E | — | Europe footprint |
U | — | USA footprint | |
UA | — | USA different terminal | |
3. | Blank | — | Standard type |
N | — | High sensitivity type | |
4. | 1A | — | Single pole normally open |
1C | — | Single pole double throw | |
5. | Blank | — | Open type |
C | — | Flux tight | |
V | — | Sealed type | |
S | — | Sealed type washable | |
6. | □ | — | Coil voltage (please refer to the coil rating data for the availability) |
Description
Outline (L×W×H) mm | 26.6 × 21.4 × 21.8 | |
Contact configuration | 1A, 1B, 1C | |
Max. Allowable Contact current(A) | 40A | |
Contact rating | Resistive load | 1A: 40A 14VDC, 1B: 30A 14VDC, 1C:NO 40A/NC 20A 14VDC |
Coil voltage | DC | 6, 9, 12, 24V |
AC | —— | |
Power consumption | DC | 1.6W, 1.2W |
AC | —— | |
Life expectancy | Mechanical(Min.) | 1×107 |
Electrical(Min.) | 1×105 | |
Dielectric strength | Open contact | 500VAC |
Contact and coil | 500VAC | |
Contact circuits | —— |
PC Board Layout