- High voltage DC load control.
- High performance DC relay for photovoltaic power generation systems, energy storage system and xEV charging device, etc.
- Complies with RoHS-Directive 2011/65/EU.
Ordering Information
HD011 |
P |
– |
1A |
H |
– |
F |
– |
C |
□ |
||||
1 |
2 |
3 |
4 |
5 |
6 | 7 |
1. | HD011 | — | Basic series designation |
2. | P | — | PCB terminal |
3. | 1A | — | Form A, single-pole, double-make(SPDM) |
4. | H | — | Contact material Ag alloy |
5. | F | — | Class F |
6. | C | — | Flux tight |
7. | □ | — | Coil voltage (please refer to the coil rating data for the vailability) |
Description
Outline (L×W×H) mm | 33.3×26.8×32 | |
Contact configuration | 1A | |
Max. Allowable Contact current(A) | 10A | |
Contact rating | Resistive load | 10A 400VDC |
Coil voltage | DC | 12~24V |
AC | —— | |
Power consumption | DC | 1.8W (Holding:0.36W) |
AC | —— | |
Life expectancy | Mechanical(Min.) | 1×106 |
Electrical(Min.) | 5×103 | |
Dielectric strength | Open contact | 2000VAC |
Contact and coil | 3000VAC | |
Contact circuits | —— |
PC Board Layout