- High duty relay with 26A 277VAC.
- UL/CUL, TUV safety approved.
- Contact gap can be greater than 1.5mm & 1.85mm.
- Conforms to European photovoltaic standard IEC 62109-1.
- Coil holding voltage can be reduced to 50~55% V of the nominal coil voltage for saving energy.
- High performance PCB power relay for photovoltaic power generation systems (solar inverter).
- Complies with RoHS-Directive 2011/65/EU.
Ordering Information
|
310 |
P |
– |
1A |
□ |
– |
F |
– |
C |
□ |
||||
|
1 |
2 |
3 |
4 |
5 |
6 | 7 |
| 1. | 310 | — | Basic series designation |
| 2. | P | — | PCB terminal |
| 3. | 1A | — | Single pole normally open |
| 4. | Blank | — | Contact gap ≥1.5mm |
| 1 | — | Contact gap ≥1.85mm | |
| 5. | F | — | Class F |
| 6. | C | — | Flux tight |
| 7. | □ | — | Coil voltage (please refer to the coil rating data for the availability) |
Description
| Outline (L×W×H) mm | 30×16×26.8 | |
| Contact configuration | 1A | |
| Max. Allowable Contact current(A) | 26A | |
| Contact rating | Resistive load | 26A 240VAC(31A 240VAC) |
| Coil voltage | DC | 12~24V |
| AC | —— | |
| Power consumption | DC | 1.5W (Holding:0.45W) |
| AC | —— | |
| Life expectancy | Mechanical(Min.) | 1×106 |
| Electrical(Min.) | 3×104 | |
| Dielectric strength | Open contact | 2000VAC |
| Contact and coil | 4500VAC | |
| Contact circuits | —— | |
PC Board Layout