- Heavy duty 140A 400VAC(for 511E), 100A 400VAC (for 511H) power type.
- SPDM contact configuration with large contact gap 3.0mm version.
- Conforms to European photovoltaic standard IEC 62109-1.
- Coil holding voltage can be reduced to 50~55% V of the nominal coil voltage for saving energy.
- High performance PCB power relay for photovoltaic power generation systems (solar inverter).
- Complies with RoHS-Directive 2011/65/EU.
Ordering Information
511 |
E |
P |
– |
1A |
H |
– |
F |
– |
C |
□ |
||||
1 |
2 |
3 |
4 |
5 |
6 | 7 | 8 |
1. | 511 | — | Basic series designation |
2. | H | — | High power type |
E | — | Extreme type | |
3. | P | — | PCB terminal (only for 511E) |
P1 | — | PCB terminal (only for 511H) | |
4. | 1A | — | Form A, single-pole, double-make(SPDM) |
5. | H | — | Contact material Ag alloy |
6. | F | — | Class F |
7. | C | — | Flux tight |
8. | □ | — | Coil voltage (please refer to the coil rating data for the availability) |
Description
Outline (L×W×H) mm | 50×41.5×46.5 | |
Contact configuration | 1A | |
Max. Allowable Contact current(A) | 100A | |
Contact rating | Resistive load | Making 40A, Carrying100A, Breaking 40A /240VACMaking 30A, Carrying100A, Breaking 30A /400VAC |
Coil voltage | DC | 12~24V |
AC | —— | |
Power consumption | DC | 3.2W (Holding:0.8W) |
AC | —— | |
Life expectancy | Mechanical(Min.) | 1×106 |
Electrical(Min.) | 1×104 | |
Dielectric strength | Open contact | 2000VAC |
Contact and coil | 4000VAC | |
Contact circuits | —— |
PC Board Layout